A
CM20
Assign the access code for Timed Reminder
set and cancel.
CM48
Designate the type of tone source to be con-
nected when answering a Timed Reminder
call.
CM49
Assign the function of the Digital Announce-
ment Trunk card.
CM90
Assign the Timed Reminder feature access key
term
to a D
, if required.
CM08
Specify the timing for Timed Reminder start.
CM41
Specify the duration of a Timed Reminder call.
Specify the duration of massage replay for
Timed Reminder.
B
DESCRIPTION
Y=0-3 Numbering Plan Group 0-3
(1)
X-XXXX: Access Code (5*, 5#)
(2)
A024: Timed Reminder Set
A025: Timed Reminder Cancel
Y=1
(1)
00: Tone source of Timed Reminder
(2)
0500: Digital Announcement Trunk
Y=00
(1)
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk No.
(2)
0C XX: Answering Message on Timed Re-
XX
: 00-63: Message No.
Y=08
(1)
00-63: Tenant No.
(2)
00-63: Message No. assigned by CM49
Y=00
(1)
My Line No. +
(2)
F0024
(1)
228: Timed Reminder start timing
(2)
0 : At preset time
1 : Before 5 minutes of preset time
Y=0
(1)
23: Timed Reminder call duration
(2)
02-14: 8-56 seconds
If no data is set, the default setting is 28-32 sec-
onds.
Y=0
(1)
52
(2)
01-99: 4-396 seconds
If no data is set, the default setting is 60-64 sec-
onds.
– 707 –
TIMED REMINDER
DATA
(EB002-EB127) assigned by
CM10/CM14
minder
Y=00
,
+ Key No.
(4 second increments)
(4 second increments)
NWA-008845-001 Rev.5.0
NOVEMBER/15/2006
32ch1011.fm