Overflow For Tas Queue - Philips Sopho 2000 IPS User Manual

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

OVERFLOW FOR TAS QUEUE

PROGRAMMING
In addition to the TAS programming (
START
CM51
Assign the destination of Call Forwarding by
Overflow for TAS Queue.
CM41
Specify the timing of Call Forwarding by
Overflow for TAS Queue.
CM51
When a call is forwarded to the VMS/station/
Attendant Console by Overflow for TAS
Queue, assign the Call Forwarding setting sta-
tion number, which is sent to the destination.
CM49
When a Digital Announcement Trunk is set as
the destination of Call Forwarding, set the
function of the Digital Announcement Trunk
as announcement service for Overflow for
TAS Queue.
END
HARDWARE REQUIRED
When a DAT is used as the destination of Call Forwarding:
DAT card or MP card (built-in DAT)
Page
DESCRIPTION
543), do the following programming.
Y=26 Day Mode
Y=27 Night Mode
Y=28 Mode A
Y=29 Mode B
(1)
00-63: Tenant No.
(2)
X-XXXXXXXX: Station No.
E000
EB000-EB127 : Digital Announcement
Y=0
(1)
42
(2)
01-99: 4-396 seconds
If no data is set, the default setting is 28-32 sec-
onds.
Y=30
(1)
00-63: Tenant No.
(2)
X-XXXXXXXX: Station No.
Y=00
(1)
000-001: Built-in DAT on MP card
002-127: Digital Announcement Trunk
(2)
1800: Announcement Service for Overflow
for TAS Queue
– 539 –
NIGHT SERVICE
OVERFLOW FOR TAS QUEUE
DATA
: Attendant Console
Trunk No. assigned by
CM10/CM14
(4 second increments)
Card No. (EB002-EB127) as-
signed by CM10/CM14
NWA-008845-001 Rev.5.0
32ch1009.fm