(6)
Card Number of Digital Announcement Trunk (PN-2DATA/4DATA) <EB002-EB127>
(a) The card number should be assigned to the FP No. 00-03 as follows.
For FP No. 00: EB002-EB031
For FP No. 01: EB032-EB063
For FP No. 02: EB064-EB095
For FP No. 03: EB096-EB127
(b) Do not assign the card number to the other FP No. than above (a).
(c) This data is not effective for a remote site of Remote PIM over IP system.
(d) The card numbers (EB000 and EB001) are dedicated to built-in Digital Announcement Trunk of
MP card.
(7)
Add-On Module number <EC00-EC31>
(a) For the FP No. 00-03, the Add-On Module number should be assigned as follows.
For FP No. 00: EC00-EC07
For FP No. 01: EC08-EC15
For FP No. 02: EC16-EC23
For FP No. 03: EC24-EC31
(b) For the other FP No. than above (a), the Add-On Module number (EC00-EC31) can be assigned
without limit as shown above (a).
(c) This data is effective for a remote site of Remote PIM over IP system.
(d) The same number (the last two digits of the data) should not be used for both DSS Console
number (E100-E131) and Add-On Module number (EC00-EC31).