Philips Sopho 2000 IPS User Manual page 355

Hide thumbs Also See for Sopho 2000 IPS:
Table of Contents

Advertisement

[For EU]
(1)
For Station-to-Station calls
START
CM08
Specify the interval of ringing tones for sta-
tion-to-station calls.
END
Interval of Ringing Tones by CM08>392/CM08>396/CM08>397
COMMAND
CM08>392
INITIAL
CM08>396
INITIAL
CM08>397
INITIAL
Internal
SLT
Ringing
term
D
External
SLT
Ringing
term
D
Special
SLT
Ringing
term
D
DESCRIPTION
0
1
0
1sON-4sOFF
1sON-4sOFF
0.3sON-0.2sOFF-0.3sON-4.2sOFF
0.25sON-0.25sOFF-0.25sON-
4.25sOFF
0.2sON-0.2sOFF-0.2sON-0.2sOFF-
0.2sON-4sOFF
0.25sON-0.125sOFF-0.25sON-
0.125sOFF-0.25sON-2sOFF
(1)
138
(2)
0 : External Ringing
1 : Internal Ringing
(See Interval of Ringing Tones by
CM08>392/CM08>396/CM08>397
below)
SETTING DATA
0.3sON-0.2sOFF-0.3sON-4.2sOFF
0.25sON-0.25sOFF-0.25sON-
4.25sOFF
1sON-4sOFF
1sON-4sOFF
0.2sON-0.2sOFF-0.2sON-0.2sOFF-
0.2sON-4sOFF
0.25sON-0.125sOFF-0.25sON-
0.125sOFF-0.25sON-2sOFF
– 337 –
DISTINCTIVE RINGING
DATA
: Initial Data
1
0
0
NWA-008845-001 Rev.5.0