Warning Tone / Co Line Call Limiter - Comdial DX-80 Installation And Maintenance Manual

Hide thumbs Also See for DX-80:
Table of Contents

Advertisement

Default Setting
At default the volume settings are as follows:
Background Music = 4
Ringing = 2
Handset = 3
Speaker (Includes speakerphone and page announcement volume) = 3
Headset = 3

Warning Tone / CO Line Call Limiter

An extension can be limited to calls that are within a specific programmed time. The DX-80 can be set to warn an
extension that the time has expired thereby advising the user to disconnect. In this mode, a system Warning Tone is
heard repeatedly when the timer has expired. This feature is useful in a lobby or retail environment where lengthy
calls are to be discouraged.
The Call Limiter can also be deployed with greater call control. In this mode, moments after the warning tone is heard
the call is disconnected automatically by the system.
The CO Line Call Limiter can be set for extensions on a per extension basis and according to call type (outgoing or
incoming or both).
Related Features
CO Line calling
Speed Dial
Last Number Redial
Related Programming
Extension – Warning Tone
Extension – Drop Call In
Extension – Drop Call Out
Call Handling – Warning Time – Outgoing Call
Call Handling – Warning Time – Incoming Call
Conditions
a)
This feature is not recommended as a "Toll Saver" option and should be used only for specific applications.
b)
Additional calls can be made at the extension following the expiration of the Warning Tone/Drop Call
operation.
Default Settings
Extension – Warning Tone = N (Range is Y/N.)
Extension – Drop Call In = N (Range is Y/N for each extension.)
Extension – Drop Call Out = N (Range is Y/N for each extension.)
Call Handling – Warning Time – Outgoing Call = 5 (Range is 1~30 minutes.)
Call Handling – Warning Time – Incoming Call = 5 (Range is 1~30 minutes.)
Programming Abstract
Determine which extensions are to be limited and for what type of call (incoming or outgoing). Then program
those extensions for the appropriate operation: Warning Tone only or Drop Call In/Out.
Program the time period for the appropriate mode(s).