The settings on this page are used to integrate the unit into an existing network.
Note
Changes to the IP address, subnet mask or gateway address are transferred
to the unit by clicking Set.
– Click Set after entering a new IP address.
– To do this, enter the old IP address followed by /reset (for instance
192.168.0.80/reset) in the address bar of your web browser. When the
camera is restarted it can only be accessed at the new IP address.
IP address
Enter the desired IP address for the camera in this field. The IP address must be
valid for the network.
Subnet mask
Enter the appropriate subnet mask for the set IP address here.
Gateway address
If you want the unit to establish a connection to a remote location in a different
subnet, enter the IP address of the gateway here. Otherwise, this field can remain
empty (0.0.0.0).
HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP
port is 80.