DINION 5100i IR
Idle state
Select Open for the output to operate as a normally open contact, or select Closed if the
output is to operate as a normally closed contact.
Operating mode
Select the way the output works.
For example, if you want an activated alarm to stay on after the alarm ends, select Bistable. If
you wish an activated alarm to stay on for ten seconds for example, select 10 s.
Output follows
Select the event that triggers the output.
Output name
The alarm output can be assigned a name here. This name appears on the Live page.
Toggle
Click the button to switch the alarm output manually (for example, for testing purposes or to
operate a door opener).
Click Set to apply the changes.
4.6.7

Alarm Task Editor

Editing scripts on this page overwrites all settings and entries on the other alarm pages. This
procedure cannot be reversed.
To edit this page, you should have programming knowledge and be familiar with the
information in the Alarm Task Script Language document and the English language.
As an alternative to the alarm settings on the various alarm pages, enter the desired alarm
functions in script form here. This will overwrite all settings and entries on the other alarm
pages.
1.
2.
3.
4.7

Network

The settings on these pages are used to integrate the device into a network. Some changes
only take effect after a reboot. In this case Set changes to Set and Reboot.
1.
2.
The device is rebooted and the changed settings are activated.
4.7.1

Network Services

This page shows an overview of all available network services. Use the checkbox to activate or
deactivate a network service. Click on the settings symbol next to the network service to go to
the settings page for this network service.
Click Set to apply the changes.
Some changes only take effect after the unit is rebooted. In this case, the Set button changes
to Set and Reboot.
Bosch Security Systems B.V.
Click Examples under the Alarm Task Editor field to see some script examples. A new
window opens.
Enter new scripts in the Alarm Task Editor field or change existing scripts in line with your
requirements.
When finished, click Set to transmit the scripts to the device. If the transfer was
successful, the message Script successfully parsed. is displayed over the text field. If it
was not successful, an error message is displayed with further information.
Make the desired changes.
Click Set and Reboot.
User manual
Configuration | en
2023-08 | V01 | F.01U.393.997