EN | 48
Red Gain
Offset factory white point alignment (reducing red introduces more cyan).
Blue Gain
Offset factory white point alignment (reducing blue introduces more yellow).
Note
It is only necessary to change the white point offset for special scene
conditions.

Installer options

Select the synchronization method for the camera: Internal for free running
camera operation; Line Lock to lock to the power supply frequency.
You can disable the buttons on the camera to prevent unauthorized change of the
camera settings. You can also disable the LED at the rear of the camera to avoid
it interfering with the image sensing of the camera.
Click the Restore all defaults button to restore the factory defaults. A
confirmation screen appears. Allow 5 seconds for the camera to optimize the
picture after a mode reset.