Tone frequencies
Tone cadences
Environmental requirements
Doorstrike relay contact
Door Phone Size
Color of System
Internet Router Module Info
59
Call recalling
1s on 400 ms off,
400 ms on 1.2 s off
440 Hz ±5 Hz, unless stated otherwise
Dial Tone
Continuous tone of 440 Hz ±5%
and 350 Hz ±5% combined
Special dial tone
800 ms on 800 ms off of 440 Hz ±5%
and 350 Hz ±5% combined
Ringback tone
1 sec on 2 sec off
Busy tone
500 ms on 500 ms off
Congestion tone
200 ms on 200 ms off
Hold tone200 ms on 200 ms off,
200 ms on 3.4 s off
Conference tone
One burst of 400 ms
NU tone
Continuous tone
Call waiting tone
100 ms on 4.9 s off
Normal working temperature
Storage temperature
Working humidity (non-condensing)
Storage humidity
Max rating
24 Volts DC
2 Amps
Height
8 inches (203 mm)
Width
2.9 inches (73 mm)
Depth
1.5 inches (38 mm)
Charcoal ref: Pantone 432C
LAN
4 x 10/100 Base-Tx Extension
DSL
10 Base-T output for an external DSL modem
ISDN
Access to B-channels on PABX PPP, MLPPP, BACP
Protocols IP V4
Authentication
PAP/CHAP
DHCP
DHCP server supports up to 100 IP addresses
Routing
Static routing
Firewall
NAT, Packet filtering
Call management Idle timers
Time of day restriction
Management
Local management
Remote management
Installation Wizard
°
°
0
C to 40
C
°
°
-40
C to +85
C
5% to 95%
°
5% to 95% @60
C

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Encorecx 2000

Table of Contents