Installing the main equipment

Equipment location

The equipment is intended for installation in a residential or office-type environment. It needs to be
mounted at a convenient working height on a dry, flat wall. The normal height is 5 feet from the floor to the
bottom of the case.
Do not place the CCU where it will be subjected to excessive levels of heat, dust or high
humidity. Locating the equipment near sources of electromagnetic radiation, such as
heavy electrical switchgear, lift machinery or electric arc welders, should be avoided.
Allow at least six inches of free space all around the CCU for ventilation.
The CCU needs to be located within six feet of an isolated, dedicated power supply outlet. The CCU must
not share the same main supply socket with any other electrical appliance.

Mounting the CCU

When a suitable location has been found, mark the screw locations on the mounting surface, using the
mounting bracket provided.
If the CCU is being mounted on masonry or plasterboard, suitable wall plugs must be used. Drill and plug
four holes in the wall at the marked locations. The holes should be deep enough to accept a one-inch screw.
16
Wall mount bracket
EncoreCX
Installation & Maintenance Manual