12. Full/Dribble Batch Function
This function allows the scale to control a 2 speed batching process with full and
dribble feed conditions.
To use this funtion, the following parameters need to be set: F6 to setting 9, F10 to the
setting of your choice, HI(dribble), OK(full feed) and LO(zero band).
Install option OP-03 or OP-04, to use the relay output of the full/dribble batch function.
The functionality and performance of this function are as follows:
Gross < Zero band
Net < Final - Preliminary
Final - Preliminary ≦ Net < Final
Final ≦ Net
HVG-WP Series
LO relay output
(Zero detection Level)
Page 33
Zero band
Preliminary value
indicator/
OK relay output
ON / Make
OFF / Break
OFF / Break
ON / Make
OFF / Break
OFF / Break
OFF / Break
OFF / Break
Final value
indicator/
indicator/
HI relay output
OFF / Break
ON / Make
ON / Make
OFF / Break
A
A
A
A
A
A
A