A&D HV-60KGL-WP Instruction Manual page 49

Hvg-wp series waterproof digital platform scale
Table of Contents

Advertisement

Item
Display
f8 5
f10 0 #
f10 1
Full/Dribble
batch sub-
f10 2
function
f10 3
f11 1 #
Address
f11 99
Hold
f12 0 # Not used
f12 1
f12 2
f13 0 #
Averaging
f13 1
f13 2
f14 0 # Stores a unit mass in the unit of a digit.
Precision
of unit
f14 1
mass
f14 2
Format
f15 0 # Format 1. (A&D general format for scales, balances)
f15 1
f16
"#" factory settings
The "nearly-zero" is within ±4 digits from zero point in the unit of kg.
The "digit", a unit of display, is equivalent to the minimum measurable mass.
HVG-WP Series
At each finish of the full/dribble batch function, the scale
accumulates the data automatically.
Use Packing articles like a powder. used for recording the bag
number and total mass.
Select the details of the full/dribble batch function (f6 9)
When the
key is pressed after final value is reached, the
F
current process is finished.
When the stability mark is displayed after final value is reached,
the current process is finished.
When the
key is pressed, the scale automatically tares and
SET
starts the full/dribble batch process. When the
after final value is reached, the current process is finished.
When the
key is pressed, the scale automatically tares and
SET
starts the full/dribble batch process. When the stability mark is
displayed after final value is reached, the current process is
finished.
Select the address for RS-422 / RS-485 for option OP-04
Use addresses from 01 to 99 are available. Scales are assigned
unique addresses and are controlled by the computer.
(RS-232C should be set to "00".)
Select the method to hold the current weight value. When the
weight value becomes nearly-zero or changes more than more
than 25% +30 digits, hold display is canceled.
The hold function is ON or OFF alternately by the
When the stability mark is displayed, the display is held.
Select readability and response
Fast response, sensitive value.
c
Slow response, stable value.
Select a storable minimum unit mass in the counting mode.
Stores a unit mass in the unit of one-eighth digit.
Stores a unit mass, if the total of the sample mass is greater than
5 digits.
Refer to "16.1. Data Format".
Format 2. (Older HV-A/ HW-A format)
Not used.
Page 47
Description
key is pressed
F
key.
F
A
A
A
A
A
A
A
A
A
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hv-60kgv-wpHv-200kgl-wpHv-200kgv-wp