Olivetti d-Copia 300 Service Manual page 203

Hide thumbs Also See for d-Copia 300:
Table of Contents

Advertisement

Code
C3200
Exposure lamp problem
• Non-lighting of the exposure lamp is
detected at the beginning of copying.
C3300
Optical system problem
• After AGC, correct input is not ob-
tained at CCD.
(This code is not displayed. The service
call counter counts the frequency of
occurrence only as for this code.)
C4000
Polygon motor synchronization
problem
• When the polygon motor starts, the
motor does not become stable even
after 20 s.
C4010
Polygon motor steady-state problem
• When high-speed rotation from low-
speed rotation is requested, the motor
does not become stable even after 20
s.
C4200
BD steady-state problem
• The VTC detects a BD error for 600
ms after the polygon motor rotation
has been stabilized.
Contents
Causes
Check procedures/corrective measures
Poor contact of
Check the connection of connector YC34
the connector ter-
on the main PCB, and the continuity across
minals.
the connector terminals. Repair or replace
if necessary.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Defective
Replace the exposure lamp or inverter
exposure lamp.
PCB and check for correct operation.
Poor contact of
Check the connection of connector YC34
the connector ter-
on the main PCB, and the continuity across
minals.
the connector terminals. Repair or replace
if necessary.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
Defective
Replace the exposure lamp or inverter
exposure lamp.
PCB and check for correct operation.
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU (see page 1-6-20).
motor.
Defective power
Check if 24 V DC is supplied to YC2-1 on
source PCB.
the main PCB. If not, replace the power
source PCB.
Defective main
Check if 24 V DC is output from YC8-10 on
PCB.
the main PCB. If not, replace the main
PCB.
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU (see page 1-6-20).
motor.
Defective power
Check if 24 V DC is supplied to YC2-1 on
source PCB.
the main PCB. If not, replace the power
source PCB.
Defective main
Check if 24 V DC is output from YC8-10 on
PCB.
the main PCB. If not, replace the main PCB.
Defective laser
Replace the LSU (see page 1-6-20).
diode.
Defective polygon
Replace the LSU (see page 1-6-20).
motor.
Defective main
Replace the main PCB and check for cor-
PCB.
rect operation.
2FD/2FF/2FG