Olivetti d-Copia 300 Service Manual page 200

Hide thumbs Also See for d-Copia 300:
Table of Contents

Advertisement

2FD/2FF/2FG
Code
C1030
Desk upper lift motor problem
• When the upper drawer of the
optional paper feeder is inserted, the
desk upper lift limit switch does not
turn on within 10 s of the desk upper
lift motor turning on. At this time,
removal and insertion of the drawer is
prompted. Even after removal and
insertion of the drawer, the upper lift
limit switch does not turn on. This
problem occurs four times
continuously.
C1040
Desk lower lift motor problem
• When the lower drawer of the optional
paper feeder is inserted, the desk
lower lift limit switch does not turn on
within 10 s of the desk lower lift motor
turning on. At this time, removal and
insertion of the drawer is prompted.
Even after removal and insertion of
the drawer, the lower lift limit switch
does not turn on. This problem occurs
four times continuously.
C1100
Paper deck motor 1* problem
• A motor over-current signal is de-
tected continuously for 1 s or longer.
1-5-26
Contents
Causes
Check procedures/corrective measures
Broken gears or
Replace the desk upper lift motor.
couplings of the
desk upper lift
motor.
Defective desk
Check for continuity across the coil. If
upper lift motor.
none, replace the desk upper lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the desk upper lift
tinuity within the connector cable. If none,
motor connector
repair or replace the cable.
terminals.
Defective desk
Check if CN1-5 on the desk main PCB
upper lift limit
goes low when the desk upper lift limit
switch.
switch is turned off. If not, replace the desk
upper lift limit switch.
Poor contact of
Reinsert the connector. Also check for con-
the desk upper lift
tinuity within the connector cable. If none,
limit switch con-
repair or replace the cable.
nector terminals.
Broken gears of
Replace the desk lower lift motor.
couplings of the
desk lower lift mo-
tor.
Defective desk
Check for continuity across the coil. If
lower lift motor.
none, replace the desk lower lift motor.
Poor contact of
Reinsert the connector. Also check for con-
the desk lower lift
tinuity within the connector cable. If none,
motor connector
repair or replace the cable.
terminals.
Defective desk
Check if CN1-7 on the desk main PCB
lower lift limit
goes low when the desk lower lift limit
switch.
switch is turned off. If not, replace the desk
lower lift limit switch.
Poor contact of
Reinsert the connector. Also check for con-
the desk lower lift
tinuity within the connector cable. If none,
limit switch con-
repair or replace the cable.
nector terminals.
Paper deck motor
Check the gears and remedy if necessary.
1 does not rotate
correctly (the mo-
tor is overloaded).
Paper deck motor
Reinsert the connector. Also check for con-
1 connector
tinuity within the connector cable. If none,
makes poor con-
repair or replace the cable.
tact.
Remarks
*: Optional

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 400D-copia 500

Table of Contents