Olivetti d-Copia 300 Service Manual page 53

Hide thumbs Also See for d-Copia 300:
Table of Contents

Advertisement

2FD/2FF/2FG
3. Release the hook of the switchback unit by
lifting the release lever.
4. Fit the switchback unit to the finisher by
hanging the hook of the switchback unit on
the loosely fitted M3 × 8 binding screws.
5. Tighten the loosely fitted M3 × 8 binding
screws.
6. Secure the switchback unit using two M4 × 12
TP screws.
7. Close the switchback unit.
8. Remove the two screws from the cover of the
finisher.
1-3-28
Switchback unit
Hook
Figure 1-3-58
Hook
M4 × 12
TP screw
Figure 1-3-59
Figure 1-3-60
Release lever
Finisher
Switchback unit
M4 × 12
TP screw
M3 × 8
binding screws
Finisher
Screws

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D-copia 400D-copia 500

Table of Contents