System Menu
Instant Chase on add machine to group
This causes machines to immediately position themselves to the Group Master position when added to a group.
MCS Presets
Pre Roll Time
This is a timecode value that sets the amount of extra timecode that a tape is re-wound by when executing a
Locate or Cycle.
Post Roll Time
This is a timecode value that sets the amount of extra time that a tape will continue for at the end of a Cycle
before rewinding to go back to the Cycle Start time.
Rewind Limit
This is the lowest timecode (or foot-frame) position that machines will go to when rewinding before they stop
automatically.
Fast Forward Limit
This is the highest timecode (or foot-frame) position that machines will go to when fast-forwarding before they
stop automatically. This is useful when using reel-to-reel tape machines to prevent the machine from
over-running the end of the tape.
Roll Back Time
This is a timecode value that sets the amount of re-wind when a Roll Back command is sent to the transport
device(s).