Rotax 912 Series Installation Manual page 113

912 series
Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

4
2
Effectivity: 912 Series
Edition 1 / Rev. 0
BRP-Rotax
INSTALLATION MANUAL
-
one each flexible wire 0,75 mm
length approx. 35 mm (1 3/8") beginning at electronic module with
one each plug socket and insulating sleeve 3,96 mm. At the new
version the cable grommet and fasten connector are integrated in
the 6-pole connector housing. See also SI-912-013, latest issue.
◆ NOTE:
One each cable grommet (2) and flat pin terminal (3)
are supplied loosely packed.
For correct assembly of the flat pin terminal strip the
wire (4) and install the cable grommet in correct
position and direction. Fix the flat pin terminal and the
cable grommet with appropriate crimping pliers. The
rubber grommet is held by the secondary crimp. Fit the
flat pin terminal in the free position of the 6-pole
connector housing until it is locked in place. Check for
tight fit.
◆ NOTE:
Faston connector and insulation sheath of the old
version are available as spare part. See also SI-912-
013, latest issue.
2
(18 AMG), brown
3
3
Fig. 72
5
08323
page 113
May 01/2007

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

912 uls 3

Table of Contents