7) External Alternator (Optional Extra) - Rotax 912 Series Installation Manual

912 series
Hide thumbs Also See for 912 Series:
Table of Contents

Advertisement

17.3.7) External alternator (optional extra)

IG
L B
1
Cyl. 2
Cyl. 4
Effectivity: 912 Series
Edition 1 / Rev. 0
INSTALLATION MANUAL
See Fig. 76, 77 and 78.
-
output: max. 600 W DC at 6000 r.p.m.
-
voltage: 14,2 V – 14,8 V
-
ambient temperature range: min. - 30 °C (-22 °F)
-
weight:
◆ NOTE:
Voltage regulator is integrated in the alternator.
Feeding wiring to external alternator (1) located on the outside of
propeller gear (see Fig. 76).
-
plus terminal (2): M6 screw suitable for ring terminal to DIN 46225
-
grounding:
-
control wiring (field circuit) (3) and warning lamp circuit (4): via
Fig. 76
03199
Cyl. 1
Cyl. 3
XXX
BRP-Rotax
max. +90 °C (194 °F)
see section 8.
(tightening torque 4 Nm (35 in.lb))
via engine block mount bracket
supplied standard plug (Sumitomo 6111-2568)
2
3
Fig. 77
04902