Prepare The Fireplace; Cast Door Assembly Removal And Installation; Glass Frame Assembly Removal And Installation; Framing - kozy heat DULUTH 55801 Installation And Operation Manual

Direct vent gas fireplace
Table of Contents

Advertisement

CAST DOOR ASSEMBLY
TO REMOVE:
Pull bottom of door out and up while lifting up to disconnect latches from mounting rod
located behind assembly.
TO INSTALL:
Lift door high enough to align latches over mounting rod, lowering slowly into position.
GLASS FRAME ASSEMBLY
TO REMOVE:
A. Locate metal bar (glass latching mechanism) below glass frame.
B.
To release glass assembly, pull latch mechanism knobs out, then immediately
down, securing metal bar onto stops.
C.
Pull bottom of glass assembly out, lifting up and off tabs at top of firebox.
WARNING: DO NOT OPERATE THIS FIREPLACE WITH THE GLASS REMOVED,
CRACKED OR BROKEN. REPLACEMENT OF GLASS ASSEMBLY, #700-07T
SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON.
WARNING: DO NOT REMOVE GLASS ASSEMBLY WHEN HOT!
TO INSTALL:
A. Place glass frame assembly top over tabs at top of firebox.
B.
Pull bottom handles out and „up‟ to secure glass frame assembly bottom.
IMPORTANT: Vent cap location must be in compliance with guidelines on page 15
of this manual.

VERTICAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A
minimum 1" (25mm) clearance on all sides of vertical vent pipe must be maintained.

HORIZONTAL TERMINATIONS

Follow vent pipe manufacturer‟s installation instructions for horizontal terminations.
Include required 1-1/2" (38mm) top clearance (at wall pass-thru) and 1" (25mm) sides
and bottom clearances for approved rigid vent systems.
IMPORTANT: Min. venting: 57" (1.45m) from floor or hearth to top of vent pipe.
IMPORTANT: Wall pass-thru required for all horizontal runs.

PREPARE THE FIREPLACE

FRAMING

PAGE 9
ROD
LATCH
Figure 9a
Pull knobs out and
down to release.
Figure 9b
Refer to vent pipe manufacturer's instructions for
specific height (H) and width (W) framing dimensions.
57" (1.45m) min. to top
of vent pipe
Figure 9c