LIGHTING AND SHUTDOWN (cont.)
LIGHTING
1.
Set thermostat to lowest setting, if installed.
2.
Turn off all electrical power to appliance. (Fan).
3.
Access gas valve & controls.
A. Push gas control knob in slightly and turn clockwise to OFF. Wait five
(5) minutes to allow any gas that may have accumulated inside firebox to
escape. If you then smell gas, STOP! Follow safety information on
previous page and front cover of this installation manual. If you don‟t
smell gas, go to next step.
NOTE: Gas control knob cannot be turned from PILOT to OFF
unless knob is pushed in slightly. Do not force.
B.
Locate pilot - follow metal tube from gas control.
(Located inside combustion chamber).
C.
Push gas valve control knob in slightly and turn counterclockwise to
PILOT. Push valve knob in and hold while repeatedly pressing piezo
igniter button until pilot is lit while continuing to hold in gas control
knob.
D. Hold gas control knob in for one (1) minute after pilot is lit.
Release gas control knob. If pilot goes out, repeat steps C-D.
When pilot is lit, proceed to step E.
CAUTION: If knob does not pop up when released, stop and
immediately call service technician or gas supplier.
If pilot will not stay lit after several tries, turn gas
control knob to OFF and call service technician or gas
supplier.
E.
Push gas control knob in slightly and turn counterclockwise to ON. The
burner can now be turned ON by depressing ON/OFF rocker switch
located on side of fireplace, or wall switch, OR by setting thermostat or
remote control to desired setting.
F.
Turn on all electric power to appliance (if applicable).
NOTE: When fireplace is initially lit, condensation will appear on glass;
this is normal in all gas fireplaces and will disappear after
several minutes.
SHUTDOWN
G. TO TURN PILOT OFF:
Depress ON/OFF rocker switch to OFF, turn off wall switch or adjust
setting on thermostat or remote control. PILOT WILL STAY LIT.
H. TO TURN PILOT OFF:
Push in and turn gas control knob to OFF. DO NOT FORCE.
NOTE: This control valve has an interlock device. If pilot has been
turned off, it cannot be relit until thermocouple has cooled,
(approximately 60 seconds).
ADJUSTING FLAME HEIGHT
The gas control valve has a HI/LO flame adjustment knob designed to allow
you to tailor the look and heat output of your fireplace. Adjust by turning
middle knob on gas control valve.