red
CAUTION:
The frequency with which the exhaust smoke outlet system is to be cleaned should be
determined according to the boiler use and the type of installation.
It is advisable that you contact an authorised service centre for maintenance and
cleaning at the end of the season because in addition to performing the above-
mentioned operations, a general check of the components will also be performed.

Decommissioning (end of season)

10.5.2.
At the end of every season, before switching off the boiler, it is
advisable to remove all pellets from the tank, using a vacuum cleaner
with a long pipe.
If, when restarting it at the general switch at the rear of the boiler, the
control panel display is not turned on, this means the service fuse may
need replacing.
There is a fuse box at the rear of the boiler, beneath the electricity
socket. Using a screwdriver, open the cover on the fuse box and
replace the fuses if necessary (3.15 A delayed).

Checking the internal components

10.5.3.
CAUTION!
The internal electrical-mechanical components must
only be checked by qualified personnel with technical
expertise in combustion and electricity.
It is therefore advisable to perform this routine annual maintenance
(perhaps with a scheduled service contract) focusing on the visual and
functional check of the following components:
Geared motor
Smoke blower fan
Smoke sensor
Exchanger fan
Pellet igniter
Pellet/water manual reset thermostat
Room/water sensor
Mother board
Panel-board protection fuses
Wiring
Maintenance and cleaning
COMPACT 24 BOILER
USE AND MAINTENANCE MANUAL