System Technical Details - RED Compact 24 Use And Installation Manual

Hide thumbs Also See for Compact 24:
Table of Contents

Advertisement

red

System technical details

3.3.
The heat and technical details of the pellet boiler system using wood pellets:
Parameter
Nominal heat output
Nominal heat output in combustion
chamber
Operating range (min – max)
Efficiency (min – max)
Average consumption rate
(min – max)
Class compliant with EN303-5
Smoke flow rate (min – max)
Draught (min – max)
Smoke temperature
Boiler water capacity
DHW flow rate
Maximum operating temperature
Max adjustable water temp.
Pellet tank capacity
Running time with average load
Diameter of flue pipe
Heating connections
Domestic Hot Water connections
Electricity supply
Power absorption (max – average)
Dimensions (WxDxH)
Boiler weight
Technical specifications and dimensions
COMPACT 24 BOILER
USE AND INSTALLATION MANUAL
Measurement unit
kW
kW
kW
%
kg/h
g/s
Pa
°C
l
l/min
bar
°C
kg
h
mm
G
G
kW
mm
kg
Technical dept. - All rights reserved - Reproduction prohibited
Compact 24
22.7
25.4
6.3 – 22.7
85.4 – 89.2
1.5 – 5.2
3
8.4 – 17.1
8.5 – 13.3
112
25
10.5
3
85
70
25
100
¾" male
½" male
50 Hz; 230V AC
420 - 100
600x660x1235
190
Chapter
3
page 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents