Programme - RED Compact 24 Use And Installation Manual

Hide thumbs Also See for Compact 24:
Table of Contents

Advertisement

red
To store, press the
display of "UT 03" to set the minutes.
Setting the MINUTES (abbreviation on the UT 03)
The display (8) shows alternately the abbreviation "UT 03" and an
indication of the clock minutes at that moment.
Use the
(increase) or
minutes.
To store, press the
display of "UT 04".
The abbreviation "UT 04" is not part of the
PROGRAMMED mode.
It is for the exclusive use of the installer or
authorised technician via restricted access.
Press button 3 again to proceed and display the
abbreviation "UT 05".

Programme

9.4.4.3.
The COMPACT boiler allows you to set up to 4 operating programmes
spread across the day or an entire week.
Each programme is distinguished by three fundamental steps:
The boiler switch-on time (which must be between
00:00 and 23:40)
The boiler switch-off time (which must be more than
the corresponding switch-on time and be maximum
23:50)
The days on which boiler switch-on and switch-off must
be ON or OFF
Let's analyse PROGRAMME 1 (summarised in the table below), which
is the first of four programmes in the programming sequence.
Abbreviation on the
display (8)
Data to enter
Switch-on
PROGRAMME 1: setting the boiler switch-on time.
UT 05
We are at step
UT 05
abbreviation
with a time value in hours and minutes. Using the
(increase) or
(decrease) keys, set the boiler switch-on time for
this programme. Each time the key is pressed, the time increases or
decreases by 10 minutes. Hold the key down to speed up the increase
or decrease progressively, so that you can make a large modification
quickly. Once the desired time has been set, store it by pressing the
key, which automatically takes you to subsequent step
PROGRAMME 1: setting the boiler switch-off time.
UT 06
We are at step
UT 06
abbreviation
with a time value in hours and minutes. Using the
Programming and settings
COMPACT 24 BOILER
USE AND MAINTENANCE MANUAL
button to take you to the subsequent
(decrease) buttons to adjust the
button to take you to the subsequent
PROGRAMME 1
UT 05
UT 06
Switch-off
Time
Time
. The boiler panel display (8) alternates the
. The boiler panel display (8) alternates the
UT 07
Days ON or OFF
On/Off 1,2,3,4,5,6,7
UT 06
.
Technical dept. - All rights reserved - Reproduction prohibited