Alarm Signals - RED Compact 24 Use And Installation Manual

Hide thumbs Also See for Compact 24:
Table of Contents

Advertisement

red
Caution!
If
the
boiler
is
NOT
manufacturer will not be held in any way liable for any ensuing
personal harm and/or property damage. In addition, the
manufacturer will not be held in any way liable for personal
harm and/or property damage due to failure to observe all the
rules specified in the manual, and also if:
all the necessary measures and/ or precautions have not
been taken when carrying out maintenance, cleaning and
repair work.
The safety devices have been tampered with or removed.
The boiler is not connected to an efficient and effective
smoke outlet system.
The room i.n which the boiler is installed is not suitably
aired
The hydraulic system has not been laid in compliance
with the provisions of the applicable laws and standards
in the country of installation.

Alarm signals

9.6.1.
In the event of an operating fault, the boiler is fitted with a
computerised monitoring system and therefore informs the user on the
display (8) how serious the fault is and where it has occurred.
The following table summarises the main alarm signals
Indication on the
display (8)
ALAR DEP FAIL
Smoke outlet pipe obstructed or back-pressure caused by
wind outside.
ALAR FAN FAIL
Fan speed too low or fan off
The smoke blower fan has shut down.
ALAR SOND FUMI
The smoke sensor has short-circuited
ALAR SIC FAIL
The pellet tank safety device has been triggered.
Malfunctioning has caused overheating. The pressure
inside the boiler is not within the parameter values set
ALAR HOT TEMP
This occurs when the temperature of the smoke reaches
and remains above 180° for too long.
ALAR NO ACC
This occurs at the first failed start-up attempt.
ALAR NO FIRE
It occurs when the boiler shuts down and when the
smoke sensor temperature is below the set threshold.
Programming and settings
COMPACT 24 BOILER
USE AND MAINTENANCE MANUAL
used
as
instructed
Type of problem
herein,
the
2
1
Solution
Check and clean the ENTIRE smoke duct or check
whether the outside wind prevents the smoke from
exiting (insert a windproof chimney).
Only once the cause of the shutdown has been
permanently remedied can the boiler be restarted.
Check how clean it is and whether dirt is slowing down
the fan. If the problem is not solved through a thorough
clean, replace the blower fan
Replace the smoke sensor
Check the parameters of the recipe used
The exchanger isn't working.
The boiler was used at maximum performance for too
long. Check the correct pressure with a pressure gauge.
Clean the inside of the exchanger and operate the boiler
at maximum performance for shorter periods of time.
Also check the quantity of pellets.
If it was the first start-up, repeat the process or check
the level of pellets in the tank.
Check the pellet igniter.
It is due to the flame dying out due to clogging or when
the pellets in the tank have run out.
Technical dept. - All rights reserved - Reproduction prohibited
Chapter
9
47
page
3
ALAR
!
5
SET
6
4
TURBO