Memory Clear

WARNING: This is a one time procedure. Do not repeat this procedure after the cash register

Memory All Clear (RAM Clear)

This step insures that the cash register is cleared of any totals or programming. After this procedure,
the cash register is ready for programming and operation.
To Perform a Memory All Clear - reset memory completely
1. Unplug the register.
2. Turn the control lock to the S position (one past PGM).
3. Press and hold the Subtotal key on the default keyboard layout.
4. Continue to hold the Subtotal key while plugging the register into a power source.
5. After hear a beep, release the Subtotal key, then press the upper left key (Paper Feed)
of the keyboard, then the lower left key (Department 5), then the upper right key
(PO), and finally press the lower right key (Cash/Tend).
PAPER
FEED
6. "= = = = = = = =.= =" will be shown on the display. After a short delay, the printer will
print the message: "RAM ALL CLEAR OK!" Memory is cleared and the default
program is installed. This is followed with the EPROM info.
7. The display will show "PLU INI". By press CASH key once, the display will show
"= = = =CC= =.=.=.". After a short waiting, "PLU INITIALIZATION
COMPLETEED!" will print. This creats 1000 PLUs. All PLUs is default Tax1(GST),
link to Department 1.
16 • Getting Started
is programmed, it causes all programs and totals to be erased.
ADD
TAX
CHECK
-
-%
+%
1
6
2
7
3
8
4
9
5
10
# / NS
CLERK
C/CONV
RETURN
CLEAR
X / TIME
11
7
8
12
4
5
13
1
2
14
0
00
15
RA
PO
VOID
CANCEL
PLU
CHARGE
9
CHECK
SUB
6
TOTAL
3
CASH
/
TEND
ER-260/265 Electronic Cash Register AU

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Er-265

Table of Contents