2.3) Operating media-Coolant
General note
Conventional

coolant

Application
Mixture
Effectivity: 912 Serie
OM Edition 2 / Rev. 0
NOTICE
WARNUNG
Conventional coolant mixed with water has the advantage of a
higher specific thermal capacity than water-less coolant.
When correctly applied, there is sufficient protection against vapor
bubble formation, freezing or thickening of the coolant within the
operating limits.
Use the coolant specified in the manufacturers documentation.
NOTICE
WARNUNG
designation
conventional e.g. BASF Glysantine
anticorrosion
waterless e.g. EVANS NPG+
* coolant component can be increased up to max. 65%.
BRP-Powertrain
Obey the latest edition of Service Instruction
SI-912-016 for the selection of the correct
coolant.
Obey the manufacturers instructions about
the coolant.
concentrate
50*
100
mixture ratio %
water
50
0
page 2-8
April 01/2010