3.2) Before engine start

3.3) Pre-flight checks

Safety

Operating media

Coolant

Effectivity: 912 Serie
OM Edition 2 / Rev. 0
Carry out pre-flight checks.
WARNING
WARNU
WARNING
WARNU
Step
1
Check for any oil-, coolant- and fuel leaks.
If leaks are evident, rectify and repair them before next
flight.
NOTICE
WARNUNG
Step
1
Verify coolant level in the overflow bottle, replenish as re-
quired up to top.
The coolant level must be between min. and max. mark.
BRP-Powertrain
Non-compliance can result in serious injuries
or death!
Ignition "OFF". Before moving the propeller.
Switch off both ignition circuits and anchor
the aircraft. Have the cockpit occupied by a
competent person.
Risk of burnings and scalds!
Hot engine parts!
Carry out pre-flight checks on the cold or luke
warm engine only!
Procedure
The coolant specifications of the section
Operating media are to be ob-
Chapter 2.3)
served!
Procedure
page 3-5