Select Either Master Or Slave Motor Setup; Set The Gate Limits - Centurion R3 Installation Manual

Swing gate automation
Hide thumbs Also See for R3:
Table of Contents

Advertisement

Select either Master or
Slave motor setup
(The gate limits of the Master and Slave
motors are set independently of each
other.)
15. Press and hold the TEST button (Fig 29) down
for 1 flash of L1, and then release. L2 will go off,
and L1 will now be flashing once per second.
16. Again press and hold TEST button, but this time
monitor the STATUS light. Release the TEST
button after 1 flash for selecting the Master
motor, or 2 flashes for the Slave motor. The
STATUS light will turn on to indicate that gate
setup is in progress.
(See Set-up Troubleshooting Guide step 16)

Set the gate limits

17. To set the closed limit press and hold the TEST
button. The master (or slave) motor will activate,
and within ±60sec the release mechanism will
engage, and the master (or slave) leaf will begin
to slowly CLOSE.
If the gate OPENS, release the TEST button and
swop the master or slave motor wires as shown
in Fig. 30. To continue the setup, press and hold
the test button as in step 17.
(See Set-up Troubleshooting Guide step 17)
18. When the connecting and drive arm hinge points are in a straight line (Fig. 22), release the TEST
button. (The gate will now be in the CLOSED position). Light L1 must now be OFF when setting the
Master, or L2 OFF when setting the Slave motor.
For fine adjustment of the gate CLOSED position, lengthen or shorten the connecting arm
accordingly.
( See Se t-up Troubleshooting Guide step 18)
Has the gate gone too far/short? Simply remove and refit the SET link. The gate will OPEN slightly. Try again
by pressing, holding and releasing the test button, as in step 17 and 18.
19. To set the OPEN limit, again press and hold the TEST button. The gate will slowly OPEN.
(See Set-up Troubleshooting Guide step 19)
20. When the gate has reached the OPEN position, release the TEST button. Light L1 must be on when
setting the Master, or L2 on when setting the Slave motor.
(See Set-up Troubleshooting Guide step 20)
Has the gate gone too far/short? Simply remove and refit the SET link. The gate will CLOSE slightly. Try again
by pressing, holding and releasing the test button, as in step 19 and 20.
TEST
Pushbutton
Figure 29 CP75 Controller TEST Pushbutton
1
Figure 30 CP75 Controller Motor Wire Connections
Page 29
2
3
4
NOTE:
TO CHANGE THE MASTER MOTOR
DIRECTION, SWOP WIRES
T O C H A N G E T H E S L AV E M O T O R
DIRECTION, SWOP WIRES
AND
.
1
2
AND
.
3
4

Hide quick links: