PEDESTAL POSITIONING FOR OUTWARD OPENING GATES
It is recommended to fit end stops in
the open position of the gate to
reduce gate movement when open.
BE SURE TO USE A
FOR THIS INSTALLATION TYPE.
b
Gate Opening
Angle (Degrees)
60
70
80
90
100
110
120
Ensure that the gate does not exceed the relevant specifications on page 9.
Recommended values are shown in bold type.
All dimensions shown are indicated in millimetres.
All recommended values will result in gates with similar opening times.
Figure 9 Pedestal Positioning for Outward Opening Gates
'LONG'
CONNECTING ARM
#
A
Gate Edge or
Hinge Centre to
Hinge Point to
Shaft Centre
Shaft Centre
240 to 530 (250)
600 to 660 (640)
150 to 440 (160)
580 to 640 (620)
100 to 400 (120)
560 to 660 (580)
100 to 400 (120)
520 to 640 (580)
100 to 400 (120)
440 to 660 (580)
100 to 380 (120)
360 to 620 (400)
100 to 260 (120)
340 to 580 (480)
b
120
B
C
Hinge Centre to
Gate Bracket
500 (500)
500(500)
500 to 550 (550)
550 to 600 (600)
550 to 600 (600)
550 to 600 (600)
550 to 650 (650)
Page 18
C
GATE LEAF IN CLOSED POSITION
o
o
o
90
100
80
o
110
o
Gate opening angle
© Centurion Systems (Pty) Ltd.
o
70
o
60
o
0