Summary of Contents for Centurion CP70R5

  • Page 2: Table Of Contents

    Table of Contents Table of Contents Company Profile ..............3 Introduction .
  • Page 3: Company Profile

    1987, and is committed to providing reliable, cost effective solutions in the field of access automation. CENTURION strives to give service and backup second to none. Our engineers are available to give sales support, installation training, and answers to technical or installation problems.
  • Page 5: Principles Of Operation

    Principles of Operation The CENTURION R3 and R5 rotary swing gate operators are both powered by a 12V DC motor using a maintenance free, lead acid battery as the primary power source. The battery is charged via a 220V mains supply or a solar panel.
  • Page 11: Gate Status Indication

    After this time the gate system can be reactivated but will shut off immediately again if a battery low condition persists. CONTACT YOUR LOCAL GATE AUTOMATION SPECIALIST OR CENTURION SYSTEMS IF YOU DISCOVER THAT THE BATT LOW SIGNAL GIVEN BY THE LED INSIDE THE HOUSE CONTINUES TO RE-OCCUR.
  • Page 13: Lightning Protection

    system will shut down and it will not be possible to operate the gate. When the keyswitch is ON, the gate system will operate normally. This is an added security feature should the property be unattended for an extended length of time. Lightning Protection The CP75 controller has on-board lightning protection.
  • Page 14 To release the manual override, proceed as follows: Unlock and remove the operator cover. Lift the controller housing fitted to a MASTER motor. This is not necessary when releasing a SLAVE motor. Allen Key Setup Tool (DO NOT USE) Swing open the manual release dust cover. Insert the allen key provided into the manual release mechanism and rotate it clockwise to release the gearbox (approximately 12 turns)
  • Page 15 To re-engage the drive (disengage manual override): Allen Key Rotate the dust cover back into position. Unscrew the allen key (counter-clockwise) until the top of the screw is flush with the top of the shaft. Replace the operator cover and lock it in position. Lower the controller housing into position (not necessary for a SLAVE motor) Page 15...
  • Page 16: Basic Maintenance

    Basic Maintenance Basic Maintenance The CENTURION system is designed to be maintenance free. However, there are some basic checks that should be carried out regularly (every six months) which will increase the long term reliability of the system, and prevent false triggering of the protection systems leading to erratic operation of the gate.
  • Page 18: Specifications

    Specifications Specifications This is a basic checklist for your gate automation system. Should you experience a fault with the system, SPECIFICATION Voltage (with CP84ER5V01 CP84ER5V01 power supply unit) 220V AC ±10% 50Hz 120mA AC Current draw (with CP84ER5V01 CP84ER5V01 power supply unit) DC Current draw (Max) Maximum solenoid lock current draw Output shaft rotational speed...
  • Page 19: Troubleshooting Guide

    THAT THE MAINS SUPPLY TO THE SYSTEM HAS BEEN ISOLATED. NB: As this product is used outside of the control of the manufacturer, CENTURION SYSTEMS (PTY) LTD, it cannot be held responsible for consequential damage as a result of the end user attempting to maintain the unit without the assistance of a qualified installer.
  • Page 20 SYMPTOM CAUSE ACTION corrosion. When was the battery last changed? † The life span of the 7A/H maintenance free battery supplied with the system is typically up to † three years. Gate does not operate but Motor fuse blown on the Replace blown fuses R3- the relays on the controller control card.
  • Page 21 SYMPTOM CAUSE ACTION input LED's are OFF. They must only light up when the c o r r e s p o n d i n g i n p u t i s activated. Try operating the system using the TEST pushbutton on the control card.
  • Page 22 SYMPTOM CAUSE ACTION Consult your installer if the problem persists. Make sure that nobody has Origin position has been shifted. accidently used the origin adjustment tool to release the manual override. Consult your installer should this be suspected. Gate opens on its own. Permanent input on one of Check that the RED LED's t h e t r i g g e r l i n e s t o t h e...
  • Page 23: Product Guarantee

    Product Guarantee Product Guarantee All CENTURION products are manufactured with extreme care, thoroughly inspected and tested. They are guaranteed for a period of 12 months, provided that proof of purchase documentation is submitted with any claim. The guarantee only covers repair, components and labour, provided that the equipment is returned to our workshop.
  • Page 24 CENTURION THE AUTOMATIC CHOICE CENTURION SYSTEMS (PTY) LTD HEAD OFFICE: TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669 148 EPSOM AVENUE, NORTH RIDING P .O. BOX 506, CRAMERVIEW, 2060 SOUTH AFRICA WEB: http://www.centsys.co.za General information e-mail: info@centsys.co.za FOR TECHNICAL SUPPORT CONTACT: SOUTH AFRICA EAST RAND.