Download Print this page

The Procedure For Setting Gate Limits On A D5-Evo Motor; Programming New Remotes On D-Series Controllers; Repairs And Servicing – Terms And Conditions - Centurion D5-EVO REPAIR Programming Manual

Hide thumbs Also See for D5-EVO REPAIR:

Advertisement

THE PROCEDURE FOR SETTING GATE LIMITS ON A D5-EVO MOTOR.

1.
Manually open the gate halfway and engage the gearbox.
2.
Press and hold the enter button
3.
Press the enter button
4.
Follow the instructions on the display, and confirm the statement on the display by
pressing the enter button
to start.
5.
Press the enter button
6.
The gate will stop in either the fully-closed, or the fully-open position when finished,
and the display will show: "Is the gate open? Yes"
7.
Confirm with the enter button
"No" using the down-arrow button
your selection.
8.
The display will indicate "Set up complete". Press the enter-button
"Setting limits" will be displayed on the screen. Now press and release the exit
button
once, to exit programming-mode.
9.
The gate motor is now ready for operation.

PROGRAMMING NEW REMOTES ON D-SERIES CONTROLLERS

7.
Press and hold the oblong button
seconds
8.
A screen will appear displaying the text "Setting Limits"; press the up arrow
until the screen displays "Remote Controls (TX)"
9.
Press and release the oblong button
10.
The screen will display "Add Remote"
11.
Press and release the oblong button
12.
The screen will display "Select Function: Trigger Gate"
13.
Press and release the oblong button
14.
The screen will now display "Time bar Remote: No"
15.
Press and release the oblong button
16.
The unit will now ask you to press your remote button
17.
Press and release the desired remote button(s)
18.
A unique ID number will appear on the screen, indicating that the button has been
successfully learned
19.
Now press the ROUND button
20.
You are good to go!
Repairs and Servicing – Terms and Conditions
All CENTURION products that are brought in for repair are serviced with extreme care, thoroughly
inspected and tested.
All Reconditioned D5-Evo units are subject to the relevant provision of the Consumer Protection Act
(68/2008), and are warranted against faulty materials and workmanship for a period of six months from
the reconditioned date, invoice date.
Please refer to http://www.centsys.co.za/our-products/product-warranties-and-exclusions for a
complete explanation of our T&Cs.
0860 0860 236 887
Technical support line: 0861 003 123 (Monday - Friday: 07h00 - 18h00, Saturday: 8h00 - 13h30)
www.centsys.com
E&OE. Centurion Systems (Pty) Ltd reserves the right to change any product without prior notice
SERVICE EXCHANGE D5 INSERT 3.indd 2
until the display shows "setting limits".
once to access the menu for setting the limits.
once, until the display shows: Clear gate area press
once; the gate will start to set the limits on its own.
if you agree (i.e. the gate is fully-open), or select
. Press the enter button
(between the two arrows) for approximately 2
(don't hold it)
(it serves as an "Enter" button of sorts)
TWICE to exit the menu
once, to confirm
once.
once

Advertisement