J3. Setting the Anti-crushing Sensitivity Profile
To select the desired sensitivity of the anti-crushing technology to either
High or Low please follow the following steps:
Step 1: Rotate the Function Dial
to the PROFILE position (E).
Step 2: Rotate the Setting Dial
to SENS hi/lo along the 'E' row
Customising
of options.
the
features
and
functions
Step 3: Press the pushbutton to
toggle the Sensitivity Profile
between High and Low.
The Status LED will change from
red to green indicating that the
High Sensitivity Profile has been
activated, or it will change to
red indicating that the Low
Sensitivity Profile has been
activated.
Step 4: Return the Function
Dial to the RUN position.

K. Verifying your setup

Should you wish to verify your settings you can rotate the Function Dial
to the function that you want to check the settings of. Then rotate the
Setting Dial to the various selection options. The status LED will light up
as green to indicate that the selected option is either On or High; or
alternatively red to indicate Off or Low.
page 30
FIGURE 65
FIGURE 66
FIGURE 67