Centurion R3 Installation Manual page 20

Swing gate automation
Hide thumbs Also See for R3:
Table of Contents

Advertisement

FOR INSTALLATIONS WHERE
THE GATE OPENS LESS THAN 90
#
A
b
Gate Opening
Angle (Degrees)
60
310 to 330 (310)
70
350 to 370 (350)
80
350 to 410 (350)
90
340 to 500 (380)
100
370 to 500 (400)
110
390 to 490 (430)
120
400 to 460 (440)
Ensure that the gate does not exceed the relevant specifications on page 9.
Recommended values are shown in bold type.
All dimensions shown are indicated in millimetres.
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is
BE SURE TO USE A 'SHORT'
CONNECTING ARM FOR THIS
INSTALLATION TYPE.
Figure 11 Determining Wall Bracket Position for Parallel Wall Mount
PARALLEL WALL MOUNT
C
GATE LEAF IN CLOSED POSITION
b
#
A
B
Hinge Centre to
Gate Centre to
Mounting Face
Bracket Centre
220 to 380 (340)
220 to 380 (340)
220 to 380 (300)
220 to 380 (300)
220 to 380 (340)
220 to 300 (240)
220 to 300 (240)
FOR INSTALLATIONS WHERE THE
O
GATE OPENS MORE THAN 90
C
Drive Arm
Hinge Centre to
Length
Gate Bracket
(700)
(250)
(700)
(300)
(700)
(350)
(700)
(420)
(700)
(480)
(700)
(500)
(610)
(500)
o
120
o
110
100
Page 20
#
A
o
90
GATE LEAF IN CLOSED POSITION
b
D
Gate opening angle
60
o
o
70
o
o
80
90
© Centurion Systems (Pty) Ltd.
O
C
o
0
o

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R5

Table of Contents