Centurion R3 Installation Manual page 19

Swing gate automation
Hide thumbs Also See for R3:
Table of Contents

Advertisement

FOR INSTALLATIONS WHERE
THE GATE OPENS 90 OR LESS
#
A
b
Gate Opening
Angle (Degrees)
60
70
80
90
100
110
120
Ensure that the gate does not exceed the relevant specifications on page9.
Recommended values are shown in bold type.
All dimensions shown are indicated in millimetres.
All recommended values will result in gates with similar opening times.
#The minimum value will ensure a clearance of 30mm if the gate is
BE SURE TO USE A 'SHORT'
CONNECTING ARM FOR THIS
INSTALLATION TYPE.
Figure 10 Determining Wall Bracket Position for Perpendicular Wall Mount
PERPENDICULAR WALL MOUNT
O
C
GATE LEAF IN CLOSED POSITION
b
#
A
Hinge Centre to
Gate Centre to
Mounting Face
Bracket Centre
140 to 180 (140)
50 to 220 (180)
180 to 220 (180)
50 to 220 (180)
180 to 260 (180)
50 to 220 (140)
170 to 350 (210)
50 to 220 (140)
230 to 370 (270)
50 to 220 (180)
290 to 400 (330)
50 to 140 (80)
340 to 410 (380)
50 to 140 (80)
FOR INSTALLATIONS WHERE THE
GATE OPENS MORE THAN 90
B
C
Hinge Centre to
Gate Bracket
(700)
(700)
(700)
(700)
(700)
(700)
(610)
o
120
o
110
Page 19
#
A
o
90
GATE LEAF IN CLOSED POSITION
b
D
Drive Arm
Length
(250)
(300)
(350)
(420)
(480)
(500)
(500)
Gate opening angle
o
o
70
o
o
100
80
90
© Centurion Systems (Pty) Ltd.
O
C
o
0
o
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

R5

Table of Contents