An automatic relay of information from the PBX when a status change occurs or an alarm is detected.
PBX
TRAP Implementation
The PBX will send the two types of TRAP as follows:
Type
Standard TRAP
Enterprise Specific
TRAP
*1
*1
Enterprise Specific TRAPs are original KX-NCP-exclusive information (Enterprise Specific MIB)
Conditions
•
Through system programming, it is possible to enable or disable this feature.
•
Up to 2 SNMP managers can be assigned.
•
This PBX supports SNMP Protocol Version 1.0 and SNMP Version 1.0-TRAP.
•
This PBX can only receive read-only MIBs. Write MIBs are not supported.
•
This PBX supports MIB II.
•
For more information regarding major and minor alarms, refer to the Installation Manual.
•
For a list of the MIB object groups supported by this PBX, refer to 21.3 Supported Management Information
Base (MIB) Table in the Appendix.
•
Through system programming, it is possible to select whether each type of TRAP (e.g., ColdStart) is sent
to the SNMP manager or not.
Installation Manual References
5.1.5 Troubleshooting by Error Log
PC Programming Manual References
13.4 [11-4-1] SNMP—System Setting
13.5 [11-4-2] SNMP—Manager
Feature Manual References
10.1.4 Local Alarm Information
Document Version 2009-12
16.1.4 SNMP (Simple Network Management Protocol) System Monitor
Sends Information
TRAP Name
coldStart
Authentication Failure
Major Alarm
Minor Alarm
PC
Manager
Description
Information is sent after turning on the power of the PBX
or resetting the PBX.
Information is sent when an unregistered Community
Name and/or Manager IP address is entered.
Information is sent when a major alarm is detected.
Information is sent when a minor alarm is detected.
Feature Manual
291