15Final Review - Valor Dream 2 Installer's Manual

Inset live fuel effect gas fire
Hide thumbs Also See for Dream 2:
Table of Contents

Advertisement

If a gap is visible between the inner sides of the front surround and the ceramic side
1.
walls, gently slide the walls forward.
Visually inspect the appliance. Clean off any marks incurred during installation.
2.
Advise the customer how to operate the appliance. Point out that lighting instruction
3.
details are on the metal plate attached at the bottom of the appliance. Explain to the
customer that the appliance has a flame failure & spillage monitoring system. Point out
the explanation of this system shown in the users instructions under "Operating the fire".
Advise that if the fire goes out for any reason; wait at least three minutes before
relighting. Stress that if the monitoring system repeatedly shuts off the fire, the appliance
should be switched off and a specialist should be consulted.
Advise the customer that they should read their Owner's guide before operating the fire
4.
and always follow the advice in the section headed "Cleaning".
Stress that no extra coals must be added over and above those supplied with the
5.
appliance and that any replacements must only be the authorised spares. Warn that
ignoring this advice could cause incomplete clearance of the products of combustion
with consequent health hazards.
Advise the customer that the appliance will operate to its maximum potential if the
6.
flue is primed during the first 20 – 30 minutes of use. To do this, simply slide the control
to its highest setting. This will also burn off any carbon deposits that may have formed
during previous use.
If using the appliance for long periods it is beneficial to change between settings. This
will also help to remove any carbon deposits that may form during use.
Recommend that the appliance should be serviced by a competent person at least
7.
annually.
If the appliance is in premises in the United Kingdom occupied by a tenant, point out that
by law a landlord must have any gas appliance, flue and pipework which is situated in a
tenant's premises checked for safety at least every 12 months.
Advise that the fire may give off a slight odour while new. This is quite normal and it
9.
will disappear after a short period of use.
Hand the literature pack with this guide to the customer.
10.
INSTALLER'S GUIDE
1 5 F I N A L R E V I E W
Page 38