Final Review - Valor Coalflame BR627 Installer's Manual

Inset live fuel effect gas fire
Hide thumbs Also See for Coalflame BR627:
Table of Contents

Advertisement

9.1
Place the fire front castings in position..
9.2
Visually inspect the appliance. Clean off any marks incurred during installation.
9.3
Hand this guide to the customer.
9.4
Advise the customer how to operate the appliance. Point out that lighting
instruction details are on the metal plate attached at the bottom of the appliance (Leave the
plate visible in front of the bottom front cover as a reminder.
9.5
Explain to the customer that the appliance has a flame failure & spillage
monitoring system. Point out the explanation of this system shown in the owner's guide
under "Operating the fire".
Advise that if the fire goes out for any reason, wait at least three minutes before relighting.
Stress that if the monitoring system repeatedly shuts off the fire, the appliance should be
switched off and a specialist should be consulted.
9.6
Advise the customer that they should read the Owner's guide before operating the
fire and always follow the advice in the section headed "Cleaning".
9.7
Stress that no extra coals must be added over and above those supplied with the
appliance and that any replacements must only be the authorised spares. Warn that
ignoring this advice could cause incomplete clearance of the products of combustion with
consequent health hazards.
9.8
Advise the customer that the appliance will operate to its maximum potential if the
flue is primed during the first 20 – 30 minutes of use. To do this, simply slide the control
to its highest setting. This will also burn off any carbon deposits that may have formed
during previous use.
If using the appliance for long periods it is beneficial to change between settings. This will
also help to remove any carbon deposits that may form during use.
This is explained in the Owner's Guide under the section 'Operating the Fire'. Point this
out to the customer before leaving.
9.9
Recommend that the appliance should be serviced and the chimney inspected by a
competent person (In the UK a CORGI registered person) at least annually.
If the appliance is in premises in the United Kingdom occupied by a tenant, point out that
by law a landlord must have any gas appliance, flue and pipework which is situated in a
tenant's premises checked for safety at least every 12 months.
9.10
For future servicing, please leave your company name and telephone number in
the box provided on page 11 of the Owner's Guide.
INSTALLER'S GUIDE
9 F I N A L R E V I E W
Page 18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Limousin br627

Table of Contents