Final Review - Valor ULTIMATE TURBOCHIM 517SF Installer's Manual

Side fan flued inset gas fires
Table of Contents

Advertisement

Figure 44 Fire front casting location
P A R T 1 4 : F I N A L R E V I E W
P A R T 1 4 : F I N A L R E V I E W
14.1 All models except black & chrome front casting Fit the fire front
casting to the front surround. Locate the two screw heads at the rear
top corners of the casting through the keyhole slots at the inner sides
of the surround. If the screw heads do not project enough or project
too far, the screws can be adjusted. Lower the casting so that it rests on
the hearth (see figure 44).
Black & chrome front casting Place the fire front casting in front of the
appliance.
14.2 Place the bottom front cover casting in position below the fire
front casting
14.3 Visually inspect the appliance. Clean off any marks incurred
during installation.
14.4 Hand this guide ,the owner's guide and the smoke match tube to the
customer.
14.5 Advise the customer how to operate the appliance. Point out that lighting
instruction details are on the rear of the bottom front cover casting.
14.6 Explain to the customer that the appliance has a flame failure & spillage
monitoring system and that the gas supply to the fire will be shut off unless the
fan is in operation. Point out the explanation of this system shown in the users
guide. Mention that in windy weather or when the mains voltage is low, a slight
click may be heard due to the fan control system switching between its normal
and boost speeds.
Advise that if the fire goes out for any reason, wait at least three minutes before
relighting.
Stress that if the monitoring system repeatedly shuts off the fire, the appliance
should be switched off and a specialist should be consulted
14.7 Advise the customer that they should read their Owner's guide before
operating the fire and always follow the advice in the section headed "Cleaning
your fire".
14.8 Stress that no extra coals must be added over and above those supplied with
the appliance and that any replacements must only be the authorised spares. Warn
that ignoring this advice could cause incomplete clearance of the products of
combustion with consequent health hazards.
14.9
Inform the customer that the gap between the top horizontal flange of
the duct backing plates and the top rear of the front covers must not be blocked.
The gap is to allow cooling air circulation along the ducting run.
14.10 Recommend that the appliance should be serviced and the flue unit
inspected by a competent person at least annually.
.
28
.

Advertisement

Table of Contents
loading

Table of Contents