1. Light the appliance. Set the slide control to the maximum burning position and leave
for one minute.
2. Set the control to the Low burning position. Isolate the gas supply at the inlet elbow.
The pilot and main burner will go out. Note the time when the pilot goes out. Listen for
a snap sound at the gas tap. Note the time when the sound is heard. This sound is
caused by an electromagnetic valve shutting off the gas supply through the tap. The valve
is located in the body of the tap. The valve should operate within 60 seconds of the pilot
going out. If the valve does not operate within this time limit do not allow the appliance
to be used until the fault has been corrected.
This monitoring system must not be adjusted, bypassed or put out of operation.
This monitoring system, or any of its parts, must only be exchanged using
authorised parts.
3. Open the isolating valve on the inlet elbow. Screw on the end cap and test for leaks.
4. Set the slider to the "Off'" position.