Dial-In Idle Time; Dial-In Max Time; Dial-Out Setup - Ness Premium H.264 DVR Setup Manual

Table of Contents

Advertisement

User's Manual

- Dial-out Setup

31
• Press ENTER, and then use UP/ DOWN to change the value.
• When it's done, press ENTER again to exit.
• Repeat the procedures until the IP is set completely.

Dial-in Idle Time

This item indicates the longest amount of time that the modem
connection remains active if there is no acknowledgement from the
remote PC. The value can be set in the range of 0 min to 600 min.

Dial-in Max Time

The item indicates the longest amount of time that the connection via
modem remains active. The value can be set in the range of 0 min to
600 min.
The Dial-out function enables user to establish dial-up modem
communication to and from the Premium H.264 DVR for remote
notification. Users can connect one modem to a Premium H.264
DVR. For more information on dial-up setting on PC, see Appendix B:
Dial-up Connections via Modem.
NOTE: The Dial-out Service is not available if there is no
modem connected to the unit.
In Network Setup menu, select <Dial-out Setup> and press ENTER
to enter the Dial-out menu. The menu displays as follows.
1. Dial-out DHCP
2. Dial-out IP
3. Dial-out Netmask
4. Dial-out Gateway
5. Dial-out DNS
6. Phone Number
7. Dial-out Account
8. Dial-out Password
9. Dial-out Idle Time
10. Dial-out Max Time
11. Connect
Dial-out Setup
192.168.254.254
192.168.254.254
OFF
192.168.254.1
255.255.255.0
1234
user
user
0 Min
0 Min
No

Advertisement