User's Manual

Alert Notification

4 options are included in this item; <OFF>, <Event>, <Alive>, and <Both>.
<OFF>:
<Event>: When the alarm is triggered, the DVR will send an alert message to
<Alive>: The DVR will send an alive message to the CMS every N second
<Both>: This enables the DVR to send both Event and Alive alert messages

Alert IP

The Alert IP must match the IP address of the computer.

Alert Port

The ports for DVR and the CMS Alert MUST be the same.

Alive Interval

To define the time interval (1 to 255 seconds) between each alive message.
< Event Full Screen >
This function allows the unit to display the alarm channel in full screen size when an alarm
is triggered.
Select <None> to disable this function; select <Main> to display the alarm channel on Main
Monitor when an alarm is triggered; select <Call> to display the alarm channel on Call
Monitor; and select <Both> to display the alarm channel on both Main Monitor and Call
Monitor.
< Event Duration >
This item determines the duration of the buzzer and Alarm Out relay function once an alarm
is triggered. The available event duration range is from 5 seconds to 999 seconds.
65
The Alert Notification is turned off.
the CMS.
just to show you that the connection between the DVR and CMS is
in effect. The time interval N can be adjusted in <Alive Interval>.
to the CMS.