5. INSTRUMENT PANEL COMPONENTS

The instrument panel components are identified as follows:
1. Main switch (1)
2. Suction switch (2)
3. Solenoid valve switch (3)

6. FIXING THE HANDLEBARS

For packaging purposes the handlebars are supplied folded; they must now be put in the working
position. Proceed as follows:
1. raise the handlebars, pulling the lever (indicated by the arrow) upwards
2. put the machine in the working position

7. SOLUTION TANK

The recovery tank must be completely empty each time the solution tank is filled.
Verify that the cap is correctly inserted in its housing (A).
Verify that the quick connection is correctly connected (B).

8. DETERGENT SOLUTION

Proceed as follows to fill the solution tank:
1. Make sure that the recovery tank is empty
2. Make sure the main switch is off
3. Remove the inlet cap located on the rear right side of the machine.
4. Fill it with clean water at a temperature not exceeding 50°C.
Add the liquid detergent to the tank in the concentration and manner indicated on the detergent
manufacturer's label. The formation of excess foam could damage the suction motor, so only use the
minimum amount of necessary detergent.
MACHINE PREPARATION