Daily Maintenance; Cleaning The Recovery Tank; Emptying Of The Solution Tank - COMAC Vispa 35E Use And Maintenance Manual

Comac vispa 35e floor scrubbing machine
Hide thumbs Also See for Vispa 35E:
Table of Contents

Advertisement

1. CLEANING THE RECOVERY TANK

1. Make sure that the power cable of the machine is unplugged from the mains socket
2. Remove the tubes attached to the connectors of the recovery tank caps.
3. Disconnect the hook securing the recovery tank on the rear of the machine.
4. Remove the recovery tank.
ATTENTION: this operation must be carried out by wearing gloves in
order to protect against contact with dangerous solutions.
WARNING: Before carrying out any type of maintenance, disconnect
the machine's power supply cable.
5. Remove the caps to open the tank.
6. Clean the filter under running water.
7. Rinse the tank and clean with a jet of water.
WARNING: this operation must be carried out by wearing gloves to
protect against contact with dangerous solutions.

2. EMPTYING OF THE SOLUTION TANK

Proceed as follows to empty the solution tank:
1. Switch off the solenoid valve switch
2. Switch off the suction switch
3. Switch off the main switch
4. Disconnect the power cable from the socket
5. Disconnect the quick connector on the front of the solution tank
6. Insert the Vispa E solution tank discharge pipe kit (optional)
WARNING: this operation must be carried out wearing gloves to protect
against contact with dangerous solutions.

DAILY MAINTENANCE

PERFORM ALL MAINTENANCE OPERATIONS IN SEQUENCE
14