1. CLEANING THE SQUEEGEE TUBE

Periodically, or whenever suction seems to be unsatisfactory, check the squeegee tube is not
obstructed. To clean it, proceed as follows:
1. Make sure that the power cable of the machine is unplugged from the mains socket
2. Remove the tube from the sleeve on the squeegee
3. Remove the other end from the recovery tank
4. Wash the inside of the tube with a water jet introduced from the side where it is
connected to the tank
5. Re-assemble the tube
WARNING: do not wash the tube running between the suction
unit and the suction cap.

2. CLEANING THE SOLUTION TANK AND FILTER

1. remove the recovery tank
2. Detach the quick connection to avoid breaking the connection itself.
3. Using a screwdriver, remove the two screws fixing the solution tank to the frame.
4. Remove the solution tank by pushing it forwards and unhooking it from the fixing bracket.
5. Loosen the solution tank cap
6. Remove the filter and clean it.
7. Rinse the tank and clean with a jet of water.
8. Reassemble the filter and cap.
9. Reassemble the tank, carrying out the above operations in the reverse order.
WARNING: this operation must be carried out by wearing gloves
in order to protect against contact with dangerous solutions.