Speci Cations; High Altitude Installations - Valor Retrofire RF24XBN Installation Manual And User's Manual

Gravity vent fireplace insert
Hide thumbs Also See for Retrofire RF24XBN:
Table of Contents

Advertisement

This appliance is intended for installation into existing
masonry or factory-built, solid-fuel burning
 replaces only.
Approvals and Codes
This appliance is certi ed to ANSI Z21.88a-2012 /
CSA 2.33a-2012 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and the USA and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installation terminating at the roof only.
Model RF24XBN is for use with Natural Gas only.
Model RF24XBP is for use with LPG only.
Conversion between fuels may only be done using the
approved conversion kits listed in the section Options.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in the
absence of local codes with the National Fuel Gas
Code, ANSI Z223.1 or the Canadian Installation Code
CAN/CGA-B149. Only quali ed licensed or trained
personnel should install this appliance.
This appliance, when installed , must be electrically
grounded in accordance with local codes, or in the
absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 or the Canadian Electrical Code,
CSA C22.1
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Speci cations

*High Altitude Installations

Input ratings are shown in BTU per hour and are
certi ed without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370 m).
Some materials or items, although safe,
Some materials or items, although safe,
may discolor, shrink, warp, crack, peel, and
may discolor, shrink, warp, crack, peel, and
so on because of the heat produced by the
so on because of the heat produced by the
 replace. Avoid placing candles, paintings,
 replace. Avoid placing candles, paintings,
photos, and other items sensitive to heat
photos, and other items sensitive to heat
around the  replace.
around the  replace.
HOT HEARTH / FLOOR! The hearth or  oor
HOT HEARTH / FLOOR! The hearth or  oor
in front of the  replace may become very
in front of the  replace may become very
hot when the  replace heats. Do not use the
hot when the  replace heats. Do not use the
hearth as a seat or shelf. Solid wood  ooring
hearth as a seat or shelf. Solid wood  ooring
in front of the  replace (if allowed) may
in front of the  replace (if allowed) may
shrink during the heating season due to heat.
shrink during the heating season due to heat.
NG
LPG
Natural
Propane
0-4,500 feet*
20,500
19,000
12,500
12,500
3.7
10.5
5.0
11.0
10.5
14.0
82-580
92-200
51
30