Mantel / Hearth Clearances
Combustible Mantel and Hearth Clearances for insert
applications must conform to those required for the
original solid-fuel burning  replace in which the RF24
insert is being installed.
Vent Materials
Use a 3”" diameter aluminium  ex liner approved for
gas venting when installing as an insert (existing
chimneys).
Use a 4”" diameter type “"B”" vent when installing with a
RA24ZC Zero Clearance Kit. See separate instructions
packaged with the Zero Clearance Kit.
The minimum vent lengths are shown below. For other
allowable con gurations, refer to the venting tables in
the National Fuel Gas Code Z223.1 or the Natural Gas
and Propane Installation Code B149.1.
Dimensions
NOTE: The glass front and hearth are very hot. Existing
wire mesh screens or free standing hearth mounted
mesh screens may be used in front of the RF24 insert to
help minimize the chance of injury.
Vent Con gurations
Failure to position the parts in accordance with
Failure to position the parts in accordance with
these diagrams or failure to use only parts
these diagrams or failure to use only parts
speci cally approved with this appliance may
speci cally approved with this appliance may
result in property damage or personal injury.
result in property damage or personal injury.
Approved Termination Required
Allowable Vent Configurations
QUALIFIED
INSTALLER
WARNING
!
Max. 16" offset if
vent height is minimal
or elbow at collar of unit
3" Liner
3" min. Bend
Radius
Minimum Vent Liner Radius
15