ALTERNATOR
RUN SOLENOID
(HOLD)
B
R
W
L
(PULL)
W
R
GY
TEMP SENDER
PK
ENGINE OIL PRESSURE
ENGINE OVER TEMP.
(115 C)
R/BK
FUEL PUMP
BK
GLOW PLUGS
(3 GLOW PLUGS USED ON RM5210)
R
FL
FL
FL
FL
B+
G
Start
SP
BU
D1
R
DIODE
ENGINE
ENGINE GROUND
MAIN
POWER
RELAY
FRAME GROUND
(ENERGIZED)
STOP - - - - - - - - NONE
RUN - - - - - - - - B+I+A; X+Y
START - - - - - - B+I+S
OPTIONAL FUSE BLOCK
IGNITION SWITCH
R
OFF RUN START
1F 1
15 A
OR
OPTIONAL FUSE BLOCK
R/W
1F 3 10 A
BU
1F 4
10 A
W
Reelmaster 5010 Series
Run (Mow) Circuits
(Serial Number Below 310000000 Shown)
(Ignition Switch in Run Position)
Power Current
Control Current
Indicator/Gauge Current
Page 9 - - 10
Rev. B
PK
R/BK
GN/W
R/BK
T
OR
BU
GLOW
RELAY
(NOT
ENERGIZED)
PK
BK
87a
30
87
VIO
BU
86
85
BN
START
RELAY
(NOT ENERGIZED)
BK
VIO
R
FL
(- -)
(+)
BATTERY
B
A
S
Y
X
I
PK
1F 2
10 A
B
I
Y
A
S
VIO
X
Y
R/W
1
2
BU
3
POWER POINT
4
BK
5
6
GROUND
BLOCK
LIGHT SWITCH
(OFF)
BK
GN/W
W
BU/W
BU
INDICATOR
LIGHTS
PK
BK
2F 1 10 A
2F 2
10 A
2F 3 10 A
2F 4
2 A
R
W/BK
PK
VIO
T
OR
R
PARKING BRAKE (BRAKE RELEASED)
GY
SEAT SWITCH (OCCUPIED)
BK
GN
NEUTRAL SWITCH (NOT IN NEUTRAL)
Y
FRONT BACKLAP (IN MOW)
BU
REAR BACKLAP (IN MOW)
Y
MOW/TRANSPORT (IN MOW)
LOWER
BK
OR
2
1
3
JOYSTICK
3
1
2
Y/BK
RAISE
OPTIONAL
AIR- -RIDE SEAT
GY/BU
UP LIMIT SWITCH (C.U. LOWERED)
1
2
3
HEADLIGHTS
GY
4
T
5
6
8
7
BK
PTO SWITCH
(ON)
PK
R/BK
BK
P1- -1
PWR 2
OUT 3
P1- -11
BN/W
R/BK
P2- -11
PWR 3
OUT 1
P1- -13
T/BK
BU
P2- -1
PWR 4
OUT 4
P1- -12
GY/BK
T/W
P1- -20
PWR LOGIC
OUT 2
P1- -14
W/BK
BN
P1- -16
KEY RUN
OUT 5
P2- -13
PK
BN
P1- -15
KEY START
OUT 6
P2- -14
VIO
W/BU
P1- -5
IN 11
OUT 7
P2- -15
T
W
P1- -7
IN 8
OUT 8
P2- -5
OR
Y/BK
P1- -3
IN 9
OUT 9
P2- -3
GY
VIO
P1- -8
IN 14
OUT 10
P2- -4
GN
GN
P1- -6
IN 7
RX
P1- -17
Y
OR/BK
P2- -16
IN 6
TX
P1- -18
BU
GN/BK
P2- -6
IN 2
TX/RX GND
P1- -19
OR
BK
P1- -4
IN 10
CAN LOW
P2- -10
Y/BK
BK/W
P2- -20
IN 4
CAN HIGH
P2- -9
GY/BU
R/W
P2- -19
IN 3
GND
P1- -2
T
P2- -18
IN 5
GND
P2- -2
Y
P1- -9
IN 13
GND
P2- -12
GN/W
P1- -10
IN 12
W
BK
P2- -7
IN 1
BU/W
P2- -17
IN 15
P2- -8
IN 16
ECM
T
BK
PK
1
4
(+)
HOUR
METER
TEMP
HR
GAUGE
(- -)
2
3
OT WARNING
GY
BU/W
DIAGNOSTIC LIGHT
MSV2 FRONT REEL ENGAGE
SV1
SV3
SVRV
SV2
MSV1 REAR
A +12
REEL ENGAGE
B
TX
BK
C
(- -)
GY
D
PK
E
RX
F
LOOP- -BACK
CONNECTOR
COMMUNICATION
PORT
A +12
PK
B
(- -)
BK
C
CAN HIGH
R/W
D
CAN LOW
BK/W