Diagnostic Display

Reelmaster 5010 machines are equipped with an Elec-
tronic Control Module (ECM) which controls machine
electrical functions. The ECM monitors various input
switches (e.g. ignition switch, seat switch, etc.) and en-
ergizes outputs to actuate solenoids or relays for the re-
quested machine function.
For the ECM to control the machine as desired, each of
the input switches, output solenoids and relays must be
connected and functioning properly.
The Diagnostic Display is a tool to help the technician
verify correct electrical functions of the machine.
IMPORTANT: The Diagnostic Display must not be
left connected to the machine. It is not designed to
withstand the environment of the machine's every
day use. When use of the Diagnostic Display is com-
pleted, disconnect it from the machine and recon-
nect loopback connector to harness connector. The
machine will not operate without the loopback con-
nector installed on the harness. Store the Diagnos-
tic Display in a dry, secure, indoor location, not on
machine.

Verify Diagnostic Display Input Functions

CAUTION
The interlock switches are for the protection of
the operator and bystanders and to ensure cor-
rect operation of the machine. Do not bypass or
disconnect switches. Check the operation of the
interlock switches daily for proper operation. Re-
place any malfunctioning switches before oper-
ating the machine.
1. Park machine on a level surface, lower the cutting
units, stop the engine and engage the parking brake.
2. Open control panel cover. Locate wire harness and
connectors near ECM. Carefully unplug loop back con-
nector from harness connector (Fig. 8).
3. Connect the Diagnostic Display connector to the har-
ness connector. Make sure correct overlay decal is posi-
tioned on the Diagnostic Display (Fig. 11).
4. Turn the ignition switch to the RUN position, but do
not start machine.
NOTE: The red text on the overlay decal refers to input
switches and the green text refers to outputs.
Electrical System
5. The "inputs displayed" LED, on lower right column of
the Diagnostic Display, should be illuminated. If "outputs
displayed" LED is illuminated, press the toggle button on
the Diagnostic Display to change to "inputs displayed"
LED.
6. The Diagnostic Display will illuminate the LED
associated with each of the inputs when that input switch
is closed. Individually, change each of the switches from
open to closed (i.e., sit on seat, press traction pedal,
etc.), and note that the appropriate LED on the Diagnos-
tic Display will illuminate when the corresponding switch
is closed. Repeat on each switch that is possible to be
changed by hand.
7. If appropriate LED does not toggle on and off when
switch state is changed, check all wiring and connec-
tions to that switch and/or test switch (see Component
Testing in this chapter). Replace any defective switches
and repair any damaged wiring.
1
1. ECM location
2. Loopback connector