G4 Internal Switches - Ricoh B051 Service Manual

Ricoh mfp service manual
Table of Contents

Advertisement

4.2.7 G4 INTERNAL SWITCHES

G4 Internal Switch 00
No.
FUNCTION
Country code
Bit 4
3
2
0
0
0
0-7
0
0
0
1
0
0
Note: In Germany, use the Universal setting for the Euro ISDN lines.
G4 Internal Switch 01 - Not used (do not change these settings)
G4 Internal Switch 02 - Not used (do not change these settings)
G4 Internal Switch 03
No.
FUNCTION
Amount of protocol dump data in
one protocol dump list
0
0: Last communication only
1: Up to the limit of the memory
area for protocol dumping
1-7
Not used
G4 Internal Switch 04
No.
FUNCTION
0-2
Not used
Auto data rate change for
transmission
(64 kbps to 56 kbps)
3
0: On 1: Off
Auto data rate change for reception
(64 kbps to 56 kbps)
0: Off 1: On
4
5-7
Not used
SM
CÓPIA NÃO CONTROLADA
COMMENTS
1
0
Country
0
1
Germany (1TR6 mode)
1
0
Universal (Europe Euro ISDN)
0
1
USA
Change this bit to 0 if you want to have a
protocol dump list of the last communication
only.
This bit is only effective for the dump list D +
Bch1.
Do not change these settings.
Do not change these settings.
0: The machine automatically changes the
1: The machine automatically changes the
Do not change these settings.
93
CÓPIA NÃO CONTROLADA
COMMENTS
COMMENTS
transmission data rate from 64 kbps to 56
kbps after 3 s if the other end did not
accept the call. This is to cope with 56 kbps
networks in the USA.
Normally, keep this bit at 0.
reception data after 6 s.
Change this bit to 1 only when there is a
communication error where the other
terminal informs 64 kbps in the SETUP
signal although it is actually 56 kbps.
BIT SWITCHES
B502

Advertisement

Table of Contents
loading

This manual is also suitable for:

B052Aficio 1224cAficio 1232c

Table of Contents