Ricoh B051 Service Manual page 213

Ricoh mfp service manual
Table of Contents

Advertisement

Rev. 04/2004
Mode No.
2
(Class 1, 2, and 3)
321
7
Normal/2nd/Trailing
edge
8
Thick/1st/Trailing edge
9
Thick/2nd/Trailing
edge
10
OHP/Trailing edge
322
Paper Transfer Charge
1
Leading edge
2
Trailing Edge
323
Paper Transfer Cleaning
1
Cleaning Negative
2
Cleaning Positive
3
Cleaning Negative
Lubrication
331
Print Start Cleaning
1
Print Start Cleaning
400*
Cleaning Bias LL1
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
401*
Cleaning Bias LL2
1
1 Color
2
2 Colors-4 Colors
3
Half Speed/1 Color
4
Half Speed/2 Colors-4
Colors
5
ID pattern
6
No Image Area
7
Jam Recovery
SM
CÓPIA NÃO CONTROLADA
Adjusts the paper transfer current at the paper edges.
[0.0 ~ 1.0 / 0.8 / 0.1 times/step] DFU
The specified values indicate how many times larger the
current at the edge is.
Adjusts the width at the paper edges where the current
specified with SP2–321 is applied.
[0 ~ 30 / 30 / 1 mm/step] DFU
The values indicate the distance from the paper edges.
Adjusts the transfer belt cleaning current. The current is
applied before and after printing jobs and during jam
recovery.
[0 ~ 255 / 150 / 0.1 µA/step] DFU
[0 ~ 255 / 150 / 0.1 µA/step] DFU
[0 ~ 255 / 50 / 0.1 µA/step] DFU
Enables/disables cleaning before printing jobs.
[0 ~ 1 / 0 / 1 /step] DFU
0: Disables
1: Enables
Adjusts the transfer belt cleaning voltage when absolute
humidity AH (g/m
0 < AH ≤ 3.5 (this is the 'LL1' humidity range) DFU
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1200 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
Adjusts the transfer belt cleaning voltage when absolute
humidity AH (g/m
3.5 < AH ≤ 8.0 (this is the 'LL2' humidity range) DFU
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
[0 ~ 2000 / 1400 / 10 Volt/step]
[0 ~ 2000 / 1600 / 10 Volt/step]
5-15
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM MODE
Function / [ Setting ]
3
) is in the following range:
3
) is in the following range:
B051/B052

Advertisement

Table of Contents
loading

This manual is also suitable for:

B052Aficio 1224cAficio 1232c

Table of Contents